The main characteristics of false loads in diesel generator sets

Safety: The AC dummy load used for the inspection and maintenance of diesel generator sets is different from the general load box. It is controlled by solid-state relays and contactless switches for connection/disconnection. The power is stepless and no arc is generated. The operator inputs through the keyboard and the microcomputer issues instructions. The solid-state relay is contactless controlled, and the inspectors do not need to touch any switches. The safety reaches 100%.

12.3

High intelligence: The AC dummy load for diesel generator set detection and maintenance integrates the triple functions of AC load, measuring instrument and data calculation, bringing the product performance to a highly intelligent level.

 

The detection data accuracy is high: The AC dummy load used for the detection and maintenance of diesel generator sets integrates the load and the instrument, collects data in real time, and the computer automatically generates the data. The data accuracy can reach 99.99%.

 

Precise power control (constant power) : The AC dummy load used for the detection and maintenance of diesel generator sets adopts solid-state relays to control power consumption components, and the high-speed power sampling adjustment module collects and compares data. Based on the load power set by the system, real-time sampling is utilized to compare the feedback power with the set power, achieving closed-loop control and power correction.

 

Multifunctional integrated LCD display: The AC dummy load for diesel generator set detection and maintenance adopts a large-screen LCD liquid crystal display with full Chinese menu prompts. During detection, it shows the three-phase phase voltage, current of each phase, active power of each phase, reactive power of each phase, power factor of each phase, frequency of each phase, neutral line current, total power and three-phase line voltage of the tested equipment.

 

Adopting a multi-CPU working mode: It uses a master and slave CPU control mode. The master CPU coordinates and uniformly completes sampling and calculation, while the three slave cpus respectively complete three-phase control tasks.

 

The performance of power consumption components is excellent: The use of columnar pure resistive power consumption components has the advantage of an excellent thermal temperature coefficient, good consistency, and a power factor that can reach above 0.99.

 

Portability: Small load volume, small floor space and easy to transport; It adopts a rotating type, making it convenient to move.

 

The measurement parameters such as load power, load working duration, and various load protections can all be set through the keyboard and adjusted at any time. The power of each phase is 100% continuously adjustable.

 

The heat dissipation system is well-developed: It adopts forced air cooling for heat dissipation, and the fan is a high-power axial flow fan, which features low noise, long service life, and an MTBF of 20,000 hours. The device automatically locks upon startup. After the detection stops for 3 minutes, the fan automatically stops rotating to ensure reliable heat dissipation of the load.

 

For more questions about the generator set, please call the Beidou Power team. More than ten years of professional production and sales of power generation equipment experience, more professional engineer team to serve you, choose Beidou power is to choose rest assured, welcome on-site factory inspection.


Post time: Dec-03-2025