  • Maintenance of Starting Storage Battery for Diesel Generator Sets

    Maintenance of Starting Storage Battery for Diesel Generator Sets

    1. Performance & Quality Compliance The performance and quality of the selected diesel generator set shall comply with relevant national standards. Diesel generator sets are widely used as standby emergency power supplies for telecommunications, finance, hospitals, schools, commercial facili...
    Read more
  • Maintenance of Starting Storage Battery for Diesel Generator Sets

    Maintenance of Starting Storage Battery for Diesel Generator Sets

    Maintenance of Starting Batteries for Diesel Generator Sets The electrolyte level shall always be kept 10–15 mm above the electrode plates. Inspect once per month and top up with distilled water (pure water) appropriately according to liquid level drop. Never add acid. Recharge the battery off-bo...
    Read more
  • Routine Maintenance of Diesel Generator Sets

    Routine Maintenance of Diesel Generator Sets

    General Maintenance Knowledge 1. Before Start-up (1) Check the levels of lubricating oil, coolant and fuel oil first. (2) Inspect pipelines and joints of the fuel supply, lubrication and cooling systems for oil or water leakage. Check electrical circuits for damaged insulation and electric leakag...
    Read more
  • Description of Diesel Generator Set

    Description of Diesel Generator Set

    Diesel generator sets are a type of AC power supply equipment for self-contained power stations. They are independent power generation devices powered by internal combustion engines, which drive synchronous AC generators to generate electricity. Modern diesel generator sets consist of components...
    Read more
  • Installation of Diesel Generator Set

    Installation of Diesel Generator Set

    Before operation, the diesel generator set shall be installed and connected. The following precautions shall be observed during installation: The installation site shall be well ventilated. Sufficient air intake shall be reserved at the generator end and proper air outlet at the diesel engine en...
    Read more
  • Measures to Prevent Diesel Engine Runaway

    Measures to Prevent Diesel Engine Runaway

    To prevent diesel engine runaway failure, the following precautions shall be taken:   (1) Do not adjust or disassemble the high-pressure fuel pump at will. If adjustment is really necessary, it shall be carried out on a dedicated test bench.   (2) Strengthen the maintenance of the dies...
    Read more
  • Handling of Diesel Engine Runaway When It Occurs

    Handling of Diesel Engine Runaway When It Occurs

    Diesel engines, especially their fuel injection pump governors, must be installed, maintained and adjusted in strict accordance with technical requirements at all times. The fuel added shall be clean and of the correct grade. Once a runaway fault occurs, the operator must keep a clear head. Immed...
    Read more
  • Tips for Maintenance of Diesel Engine Filters

    Tips for Maintenance of Diesel Engine Filters

    The engines of tractors and agricultural transport vehicles are all equipped with an air filter, an oil filter and a diesel filter, commonly known as the “three filters”. The working condition of the three filters directly affects the operating performance and service life of the engi...
    Read more
  • Causes of Diesel Engine Bearing Seizure

    Causes of Diesel Engine Bearing Seizure

    Failure to use lubricating oil according to seasons. Different grades of lubricating oil shall be used in different seasons. Some diesel engines suffer from bearing seizure simply because low-viscosity lubricating oil is used in summer, which fails to form an oil film on the contact surface of cr...
    Read more
  • Selection of Commonly Used Diesel Generators

    Selection of Commonly Used Diesel Generators

    Some diesel generators are required to operate continuously for a certain period of time or frequently as the main power supply for electrical loads. Such generators are called regular power generators. Regular power generators can be classified as either regular units or backup units. In areas s...
    Read more
  • The combination of gear reduction motor modules

    The combination of gear reduction motor modules

    In the structural design of gear reduction motor modules, it is essential to take into account the design of joint connection elements. To ensure module interchangeability, joint connections shall serve the functions of positioning and coupling. Their shape, dimensions and fits should comply with...
    Read more
  • Fault inspection of the motor(3)

    Fault inspection of the motor(3)

    When the motor is running, there is noise. The fault occurred in the mechanical and electromagnetic parts of the motor. Here is the professional English translation of the motor fault diagnosis text, in standard technical English: The method of differentiation is as follows: run the motor first ...
    Read more