News

  • Maintenance of Starting Storage Battery for Diesel Generator Sets

    Maintenance of Starting Storage Battery for Diesel Generator Sets

    Maintenance of Starting Batteries for Diesel Generator Sets The electrolyte level shall always be kept 10–15 mm above the electrode plates. Inspect once per month and top up with distilled water (pure water) appropriately according to liquid level drop. Never add acid. Recharge the battery off-bo...
    Read more
  • Routine Maintenance of Diesel Generator Sets

    Routine Maintenance of Diesel Generator Sets

    General Maintenance Knowledge 1. Before Start-up (1) Check the levels of lubricating oil, coolant and fuel oil first. (2) Inspect pipelines and joints of the fuel supply, lubrication and cooling systems for oil or water leakage. Check electrical circuits for damaged insulation and electric leakag...
    Read more
  • Basis for Selecting Diesel Generator Sets

    Basis for Selecting Diesel Generator Sets

    Criteria for Selecting Diesel Generator Sets The performance and quality of the selected diesel generator set shall comply with relevant standards. Diesel generator sets are widely used as emergency standby power supplies for telecommunications, finance, hospitals, schools, commercial establishm...
    Read more
  • Description of Diesel Generator Set

    Description of Diesel Generator Set

    Diesel generator sets are a type of AC power supply equipment for self-contained power stations. They are independent power generation devices powered by internal combustion engines, which drive synchronous AC generators to generate electricity. Modern diesel generator sets consist of components...
    Read more
  • Unattended Control Instructions for Diesel Generator Sets

    Unattended Control Instructions for Diesel Generator Sets

    Unattended Control Instructions for Diesel Generator Sets 1. Turn on the power switch and set the panel to the automatic position. The status indicator light will turn on. At this point, the program enters the automatic standby state. 2. When the city power grid loses power, the controller will ...
    Read more
  • Installation of Diesel Generator Set

    Installation of Diesel Generator Set

    Before operation, the diesel generator set shall be installed and connected. The following precautions shall be observed during installation: The installation site shall be well ventilated. Sufficient air intake shall be reserved at the generator end and proper air outlet at the diesel engine en...
    Read more
  • Selection of Diesel Generator Sets

    Selection of Diesel Generator Sets

    Eight Common Pitfalls to Avoid When Buying Diesel Generator Sets.   Confusing KVA with KW. Sellers exaggerate power by equating KVA directly to KW. In fact, KVA stands for apparent power while KW is active power, with the conversion formula: 1 KVA = 0.8 KW. Imported units usually adopt KVA a...
    Read more
  • The diesel engine shall undergo major overhaul in the following conditions

    The diesel engine shall undergo major overhaul in the following conditions

    Conditions for Diesel Engine Major Overhaul Obvious power drop. When the accelerator is set to the rated position, the actual output power of the diesel engine is only about 60% of the rated power, failing to drive the matched load normally. The power still cannot be restored after maintenance an...
    Read more
  • Measures to Prevent Diesel Engine Runaway

    Measures to Prevent Diesel Engine Runaway

    To prevent diesel engine runaway failure, the following precautions shall be taken:   (1) Do not adjust or disassemble the high-pressure fuel pump at will. If adjustment is really necessary, it shall be carried out on a dedicated test bench.   (2) Strengthen the maintenance of the dies...
    Read more
  • Handling of Diesel Engine Runaway When It Occurs

    Handling of Diesel Engine Runaway When It Occurs

    Diesel engines, especially their fuel injection pump governors, must be installed, maintained and adjusted in strict accordance with technical requirements at all times. The fuel added shall be clean and of the correct grade. Once a runaway fault occurs, the operator must keep a clear head. Immed...
    Read more
  • The causes of diesel engine runaway operation

    The causes of diesel engine runaway operation

    (1) Causes of Diesel Engine Runaway Caused by Excessive Diesel Supply ① The ball head of the plunger adjusting arm or rack adjusting arm fails to fit into the groove of the adjusting fork, leaving the plunger at the rated fuel supply position. ② Inflexible rotation of the fuel pump plunger. This...
    Read more
  • Tips for Maintenance of Diesel Engine Filters

    Tips for Maintenance of Diesel Engine Filters

    The engines of tractors and agricultural transport vehicles are all equipped with an air filter, an oil filter and a diesel filter, commonly known as the “three filters”. The working condition of the three filters directly affects the operating performance and service life of the engi...
    Read more
123456 Next > >> Page 1 / 67