What are the conditions for the difficulty of starting a diesel generator set?

1. Circuit failure. Wrong wiring connection; poor contact; insufficient battery capacity.
2. The oil circuit is an oil circuit, the oil circuit is blocked, the diesel filter is blocked, the fuel transfer pump does not supply oil, the injection hole of the injector is blocked by carbon deposits, the injection pressure is too low, and the operation is not working.
3. The injection time is wrong.
4. The gas distribution phase is wrong.
5. The temperature is too low to end the compression. The temperature is too low.
6. Poor compression, excessive wear of piston rings and cylinder liner, poor valve sealing, oily seal, poor sealing, low vacuum at the intake port, small intake air volume, leakage of gas entering the cylinder during compression, and low pressure at the compression end , the temperature is low so that diesel does not exist.

8.20有