The control section of the excitation system
The automatic excitation regulator for the first phase consists of a silicon-controlled rectifier power unit, a phase-shift triggering unit, a DC amplification unit, a voltage feedback unit, a deviation control unit, a DC power supply unit, and a power supply monitoring unit. The rectifier power ...Read more -
Generator knowledge: What are the rated parameters of synchronous generators
The main rated electrical parameters of a synchronous generator are: (1) Rated power (pe) refers to the rated active power that the generator can output under rated operating conditions, measured in kilowatts (kW) or megawatts (MW). (2) Rated voltage (Ue) refers to the line voltage of the genera...Read more -
Method for treating rotor insulation with insulation cleaning agent for electromechanical equipment
The method of cleaning generator rotor insulation using mechanical and electrical equipment cleaning agent Selection of cleaning agent 1. Good insulation performance, with a withstand voltage of 25kV or above; 2.It is non-flammable and volatile at room temperature; 3. Can clean dust, oil stain...Read more -
The inspection method for the insulation of the generator rotor and the handling method for the decrease in resistance
Inspection methods for rotor insulation Inspection method after shutdown: Use a 1000-volt multimeter to test the insulation between the rotor and the ground. When the insulation resistance is lower than 2 MΩ, it should be dealt with. Inspection method during operation: During operation of...Read more -
The main reasons for the reduction of the insulation of the generator rotor
The main reasons for the reduction of the insulation of the generator rotor 1.1 The rotor’s insulation resistance drops below the allowable value due to moisture absorption. This can occur if the generator is shut down for a long period, or if the environment is humid for other reasons. &n...Read more -
Performance Comprehensive Analysis of Generator Automatic Switching System
(1). Automatic Generator Switching Function: 1. Self-starting Function: · When the mains power is lost, the unit automatically starts. · Number of allowed startups: three times. · Time for each startup and closing the circuit breaker: 5 to 8 seconds. · When the startup is successful once, the tot...Read more -
How should the protection parameters of the generator set be set
How should the protection parameters of the generator set be set? The diesel engine used in the diesel generator set is prone to sudden and severe damage during use. It is necessary to install protection devices on the generator set. When the oil pipe of the generator bursts and there is a lack o...Read more -
Detailed Explanation of Generator Set Parallelization Project
I. Main Functions of the Parallel Cabinet The automatic paralleling system provides a fully electronic protection system for faults such as short circuits, overloads, overvoltages, and reverse power in the generator sets. This ensures the safe and reliable operation of the generators. When multip...Read more -
Analysis and Suggestions for Electric Brush Faults in Circuits
Enhance the understanding of the oxide film on the brush surface, and establish the conditions for its formation and normal operation: Several recent failures were mainly caused by the inability to form a lubricating layer on the oxide film of the brush surface. The formation of the oxide film r...Read more -
Common causes and solutions for faults of brushes and collector rings
Common faults of the brush during operation include overheating, generating sparks, severe damage to the brush holder and the collector ring. From the causes of overheating faults, there are mainly the following aspects: 1. Overheating due to poor ventilation: Poor ventilation mainly results fro...Read more -
How to identify and handle the situation when the oil pressure is too high
1. Phenomenon When the engine is operating, the oil pressure gauge indicates an excessively high oil pressure value that exceeds the specified limit. 2. Cause Analysis From the principle that the lubrication system generates pressure by the oil pump, it can be known that the lubricating oil in t...Read more -
A Brief Discussion on the Generator Grid Connection Breaker System
Power plants often use generators as backup power sources to cope with power outages in the grid, failures of power supply equipment, and equipment maintenance. When a power outage occurs, the generator should automatically start within a few seconds to supply power to the feeder cabinet and elec...Read more